Michigan · NOAA station KDTW

Heating with a mini-split in Detroit, MI

The short answer

In Detroit, a median ENERGY STAR cold-climate mini-split heating a 24,000 BTU/h design load should cost about $1,388 a year: $739 more than natural gas (90% efficient), and 61% less than electric resistance. The 99% design temperature is 9°F, so capacity at 5°F rarely decides anything here.

9°F99% design temp
5,563Heating degree days (65°F)
1,341Hours a year at or below 32°F
43Hours a year at or below 5°F
21.3¢Electricity per kWh (Michigan)

The winter you are actually buying for

This is Detroit's average year of hourly temperatures from 2015 through 2024 (81,807 readings at Detroit Metro Wayne County Airport, 93.3% of all hours). The dashed line is the 99% design temperature: only 1% of hours are colder.

0437873 -10°0°10°20°30°40°50°60° 99% design temp 9°F Outdoor temperature (°F), 5-degree bands · y-axis: hours per year
Hours per year in each 5°F band below 65°F in Detroit. Coldest recorded hour in the ten years: -13°F.

What it costs, by fuel

24,000 BTU/h design load, Detroit (90% furnace/boiler)
Mini-split heat pump $1,388/yr
Natural gas $648/yr
Heating oil $1,448/yr
Propane $1,463/yr
Electric resistance $3,564/yr

Mini-split modeled as a median certified cold-climate unit sized to cover the load at 9°F. Seasonal efficiency in Detroit's weather: COP 2.57. In 92 hours a year the load exceeds capacity and the estimate adds electric backup.

Three house sizes

Estimated yearly heating cost, Detroit MI
Design loadHeat pumpGasOilPropaneResistanceSeasonal COPSystems that cover it
12,000 BTU/h$694$324$724$732$1,7822.5710,960 of 14,941
24,000 BTU/h$1,388$648$1,448$1,463$3,5642.575,436 of 14,941
36,000 BTU/h$2,082$972$2,172$2,195$5,3462.572,740 of 14,941

The last column counts ENERGY STAR cold-climate systems whose published 5°F and 47°F capacities, joined by a straight line, still reach the design load at Detroit's 9°F. How sizing works.

Not a quote. Real bills depend on insulation, thermostat habits, installation and your own Manual J. Use this to decide whether a heat pump is worth pricing, then get two local quotes.

Questions people ask

Will a mini-split work in Detroit in winter?

Yes, if it is a cold-climate model. Detroit's 99% design temperature from 2015–2024 hourly data is 9°F, and the lowest hour recorded was -13°F. The median ENERGY STAR cold-climate unit keeps 88% of its 47°F heating capacity at 5°F. Hours per year at or below 5°F in Detroit: 43.

Is a heat pump cheaper than natural gas in Detroit?

At a 24,000 BTU/h design load, we estimate $1,388 a year with a median cold-climate mini-split versus $648 for natural gas at 90% efficiency, using 21.28¢/kWh electricity and 2024 Michigan fuel prices. That is $739 more than natural gas.

How big a mini-split do I need in Detroit?

Size to your home's heat loss at 9°F, not to square feet. For a 24,000 BTU/h load, a unit shaped like the median certified system needs about 26,833 BTU/h of 47°F capacity. 5,436 of the 14,941 certified systems cover that load at 9°F.

More near Detroit